 How to reset Jin501

Case Study  If you found that your Jin501 don't work after being configured, you must do something wrong with it, so the best way is restoring factory defaults. You can reset your Jin501 as follows:
1.       connect Jin501 with your computer.
2.       configure the ip of your computer with 192.168.10.50
3.       keep on pressing the “reset” button which is in the base of your Jin501, power Jin501 at the same time.
4.       telnet 192.168.10.1 in your computer
5.       after entering, input 3.
6.       now the factory defaults has been restored.



 
     Related Links
· More about Case Study
· News by alex


Most read story about Case Study:
PBX to Viop


     Article Rating
Average Score: 0
Votes: 0

Please take a second and vote for this article:

Excellent
Very Good
Good
Regular
Bad


     Options

 Printer Friendly Printer Friendly


Associated Topics

Case Study

"Login" | Login/Create an Account | 0 comments
The comments are owned by the poster. We aren't responsible for their content.

No Comments Allowed for Anonymous, please register




All logos and trademarks in this site are property of Telecomchinasourcing.com © 2005
PHP-Nuke Copyright © 2005 by Francisco Burzi. This is free software, and you may redistribute it under the GPL. PHP-Nuke comes with absolutely no warranty, for details, see the license.
Page Generation: 0.27 Seconds